Negotiable
The date of payment from buyers deliver within days
Beijing
Long-term effective
2021-06-17 01:32
417
Company Profile
Wuxi Haibang Mechanical & Electrical Manufacturing Co., LtdBy certification [File Integrity]
Contact:wxhaibang(Mr.)
Email:
Telephone:
Phone:
Area:Beijing
Address:Beijing
Website:http://www.vacuumcontactor.com/ http://wxhaibang.energycn.net/
General Description:
Hai Bang High Voltage Vacuum Contactor is applicable on AC 50-60Hz power systems, rated voltage up to 7.2 kV, rated current 160A, 250A, 400A, 630A. This type of high voltage vacuum contactor is used to directly or remotely connect and disconnect the main circuit and frequently control capacitive loads, AC motors, transformers and other electrical equipment. This type of 7.2kV vacuum contator is widely used in power grid reactive power compensation, chemical industry, metallurgy, water supply and drainage treatment, underground coal mine equipment and other occasions. The altitude of the environment where the Vacuum Contactor is used does not exceed 1000 meters above sea level.
Types JCZ5-7.2J/D-160-1.6 JCZ5-7.2J/D-250-2.5 JCZ5-7.2J/D-400-4.0 JCZ5-7.2J/D-630-6.3 |
Application Condition:
a. Ambient Air Temperature: -25℃~+40℃,24-hour average must NOT exceed +35℃;
b. Altitude: 1000m or Lower;
c. Relative Humidity: Daily average less than 95%, Monthly average less than 90%, Must NOT exceed 50% when Ambient Air Temperature reaches +40℃;
d. Operation Environment: Ambient air shall not be contaminated by corrosive, flammable or explosive gas and water vapor, Contamination Level: Level III;
e. Installation of JCZ5 7.2kV Vacuum Contactor:
When operating, the tilt angle between the surface of installed 7.2kV Vacuum Contactor and the horizontal plane shall NOT exceed 5°.
Note: In case the above conditions cannot meet the user's requirements, the user can negotiate with the manufacturer for special treatment of the product.
Technical Data:
Name |
Unit |
Value |
||||
Main circuit |
Rated working voltage (Ue) |
kV |
7.2 |
|||
Rated working current (Ie) |
A |
160A,250A,400A,630A |
||||
Rated frequency (fr) |
Hz |
50~60 |
||||
Rated connecting capacity |
A |
10Ie (AC-4) |
||||
Rated breaking capacity |
A |
8Ie (AC-4) |
||||
Rated short time withstand current |
A |
10Ie |
||||
Rated peak withstand current |
A |
25Ie |
||||
Rated short circuit duration |
s |
4 |
||||
Ultimate breaking capacity |
kA, time |
6.3/3 |
||||
Power frequency withstand voltage |
Wiring terminal to earth |
kV |
32 |
|||
Vacuum breaks |
kV |
32 |
||||
Lightening impulse withstand voltage |
kV |
60 |
||||
Rated single capacitor breaking current (C2) |
A |
160 |
||||
Control circuit |
Rated voltage (Us) |
V |
AC 110/220/380 |
|||
DC 110/220 | ||||||
Rated power (Ps)electric holding |
VA |
≤1000/100 (absorbing/holding) |
||||
Rated power (Ps) mechanical holding |
VA |
≤900/600 (Closing/opening) |
||||
Auxiliary circuit |
Form |
(3a+2b)~(6a+5b) |
||||
Rated value |
AC 380V/5A, |
|||||
DC 380V/1A | ||||||
Control circuit, auxiliary circuit to earth power frequency withstand voltage |
kV |
2 |
||||
Rated operating frequency |
Long-term |
time/h |
300 |
|||
Short-term |
time/h |
600 |
||||
Mechanical endurance |
10000 times |
100 |
||||
Electrical endurance |
10000 times |
25(AC-3), 10(AC-4) |
||||
Mechanical characteristics |
Closing time |
ms |
≤200 |
|||
3-phase asynchronous time |
ms |
≤3 |
||||
Original opening time |
ms |
≤100(electric holding), ≤60(mechanical holding) |
||||
Closing tripping |
ms |
≤5 |
||||
Remark: 1. rated control voltage can be made according to customer’s requirements. |
Our Advantages:
1. Extensive production experience: we are specialized in all kinds of vacuum contactors with an experience of 18 years, and we have has passed the ISO9001:2008 version of the quality system certification.
2. Quality design: we can provide high-quality design to meet various application needs, so that you could get the most cost-effective products from us. We have got patents for Plateau Type vacuum contactor and vacuum contactor of large current. The high-voltage horizontal vacuum contactor and the low-voltage large-current vacuum contactor adopt solid-sealed pole type, which can be mounted on the wall side or fixedly.
3. Complete production facilities: owning advanced processing equipment such as laser cutting machines, CNC machining centers for production, laying the foundation for qualified production.
4. Strict testing procedures: owning advanced testing instruments such as switch intelligent testing systems, power frequency withstand voltage testers, etc., meeting the requirements of the product design and process, providing reliable testing data.
5. Best after-sale service: The warranty of our vacuum contactor is normally 12 months. During the warranty period, if there is a failure or quality problem, we will guarantee the product according to the standard.
FAQ:
Q1:Are you a manufacturer, trading company or a third party?
A:We are a manufacturer, and we have builded up our company since 2003.
Q2:What is your minimum order quantity?
A:The minimum quantity is 1 set.
Q3:What is the delivery time of the vacuum contactor?
A:Delivery time:7 days for 30 sets or below; 14 days for 50-100 sets.
Q4:About the after-sale service, how can you solve the problems occurred of your overseas customer in time?
A:The warranty of our vacuum contactor is normally 12 months, during this period, we will arrange the international express immediately, to make sure the replace parts to be delivered as soon as possible.
http://www.vacuumcontactor.com/